Salvaged a DS3 hotcut Friday night. Circuit was provisioned for B1 BBDCS to B3 BBDCS. Circuit slipped through quality control. Didn't notice until had customer down on old path. Couldn't map new path to bring customer back up on new path. Found vacant timeslot on installed OC48 facility between the two BBDCS's. Mapped the B1 appearance to the available timeslot on the installed OC48 facility. Mapped the B3 appearance to the same available timeslot on the same installed OC48 facility. Customer came up on new path at that time. Had on-call provisioner redraw circuit path in circuit data base.